ALPINE SOLAR

Operating

Solar power plant

Capacity
66 MW
Primary fuel
Solar
County
Los Angeles County
Operator
FIRST SOLAR ENERGY LLC
Status
Operating
Commissioned
2013
EIA plant ID
57295
Generators
1
Technology
Solar Photovoltaic
Net generation (2024)
119 GWh
Capacity factor (2024, EIA nameplate)
20%
Data vintage
EIA-860 2024 final; EIA-923 2022-2024 final
Coordinates
34.7892, -118.5047

See it on the map

ALPINE SOLAR, a 66 MW Solar power plant in Los Angeles County, California. Operated by FIRST SOLAR ENERGY LLC, commissioned 2013.

How ALPINE SOLAR compares

With 66 MW of capacity, ALPINE SOLAR ranks 207th among the 874 operating power plants Bywatts maps in California and 27th of the 303 operating Solar plants in the state. It accounts for about 0.9% of California's operating Solar capacity and under 0.1% of all operating capacity in the state. Nationally it is the 39th-largest of the 639 operating Solar plants in the database. Commissioned in 2013, it is newer than 72% of the 859 operating California plants with a recorded commissioning year. Its operator, FIRST SOLAR ENERGY LLC, runs 11 operating plants in California totaling 1,678 MW. It shares Los Angeles County with 110 other operating plants, including AES ALAMITOS LLC and CASTAIC.

EIA-860 lists 1 generator at the site with 66 MW of nameplate capacity, all solar photovoltaic technology. Net generation was 119 GWh in 2024 (a 20% capacity factor), down 28% from 2022.

Grid neighborhood

The nearest named substation is NEENACH, about 1.0 miles away; the closest transmission line found within 10 miles is a 500 kV line owned by AZUSA LIGHT & POWER, about 5.6 miles away. Another 73 operating power plants totaling 6,284 MW sit within 25 miles; the largest is CASTAIC (1,682 MW, Hydro).

Computed by Bywatts from HIFLD power plant, substation and transmission line records and EIA-860/923 survey data; distances are straight-line. Sources and methodology

Weather peril exposure

ALPINE SOLAR is a 66 MW solar power plant in Los Angeles County, CA, operated by FIRST SOLAR ENERGY LLC, commissioned in 2013. Los Angeles County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 2.0 of 5 at the 25th national percentile. Earthquake is the leading peril, rated Very High by FEMA at the 99th percentile.

2.0 of 5Modeled catastrophe exposure
ModerateExposure band
EarthquakeLeading peril
StandardInsurability signal

Los Angeles County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
EarthquakeVery High99th5.0 of 526%0.09
WildfireVery High98th4.9 of 546%<0.01
Riverine floodingVery High92nd4.7 of 521%4.0
Heat waveRelatively High50th3.0 of 5<1%9.5
Coastal floodingRelatively High34th2.4 of 51%2.2
TornadoRelatively High13th1.5 of 51%0.49
HailRelatively Moderate12th1.5 of 56%0.10
Strong windRelatively Moderate0th1.0 of 5<1%0.15
Winter weatherRelatively Moderate0th1.0 of 5<1%6.6
LightningVery High0th1.0 of 5<1%8.4

Perils not assessed in Los Angeles County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "No Rating" for this county
Ice stormFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 1.5 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.5 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 66 MW solar array

At an assumed replacement value of $0.90 per watt, or $59.4M insured, the modeled expected annual loss for a fixed tilt ground mount array in Los Angeles County is $23,281 a year, $353 per MW, 0.04% of insured value.

Heat is modeled as a production risk rather than a property loss: 1.5% of annual yield in this county.

Insurability signal: Standard. Wildfire carries 46% of modeled loss.

Model hail, wind and flood exposure for Los Angeles County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.