IMPERIAL SOLAR ENERGY CENTER SOUTH

Operating

Solar power plant

Capacity
130 MW
Primary fuel
Solar
County
Imperial County
Operator
CSOLAR IV SOUTH LLC
Status
Operating
Commissioned
2013
EIA plant ID
57490
Generators
1
Technology
Solar Photovoltaic
Net generation (2024)
264 GWh
Capacity factor (2024, EIA nameplate)
23%
Data vintage
EIA-860 2024 final; EIA-923 2022-2024 final
Coordinates
32.6633, -115.6583

See it on the map

IMPERIAL SOLAR ENERGY CENTER SOUTH, a 130 MW Solar power plant in Imperial County, California. Operated by CSOLAR IV SOUTH LLC, commissioned 2013.

How IMPERIAL SOLAR ENERGY CENTER SOUTH compares

With 130 MW of capacity, IMPERIAL SOLAR ENERGY CENTER SOUTH ranks 128th among the 874 operating power plants Bywatts maps in California and 18th of the 303 operating Solar plants in the state. It accounts for about 1.8% of California's operating Solar capacity and 0.2% of all operating capacity in the state. Nationally it is the 24th-largest of the 639 operating Solar plants in the database. Commissioned in 2013, it is newer than 72% of the 859 operating California plants with a recorded commissioning year. It shares Imperial County with 33 other operating plants, including IMPERIAL VALLEY SOLAR LLC and EL CENTRO.

EIA-860 lists 1 generator at the site with 129 MW of nameplate capacity, all solar photovoltaic technology. Net generation was 264 GWh in 2024 (a 23% capacity factor), down 9% from 2022.

Grid neighborhood

The nearest named substation is IMPERIAL VALLEY (500 kV), about 5.0 miles away; the closest transmission line found within 10 miles is a 230 kV line owned by SAN DIEGO GAS & ELECTRIC, about 1.5 miles away. Another 16 operating power plants totaling 1,666 MW sit within 25 miles; the largest is IMPERIAL VALLEY SOLAR LLC (434 MW, Solar).

Computed by Bywatts from HIFLD power plant, substation and transmission line records and EIA-860/923 survey data; distances are straight-line. Sources and methodology

Weather peril exposure

IMPERIAL SOLAR ENERGY CENTER SOUTH is a 130 MW solar power plant in Imperial County, CA, operated by CSOLAR IV SOUTH LLC, commissioned in 2013. Imperial County carries low modeled catastrophe exposure in the FEMA National Risk Index, scoring 1.4 of 5 at the 9th national percentile. Earthquake is the leading peril, rated Relatively High by FEMA at the 99th percentile.

1.4 of 5Modeled catastrophe exposure
LowExposure band
EarthquakeLeading peril
StandardInsurability signal

Imperial County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
EarthquakeRelatively High99th5.0 of 558%0.15
Riverine floodingRelatively High77th4.1 of 529%1.5
Heat waveRelatively Moderate70th3.8 of 5<1%16.9
WildfireRelatively Low52nd3.1 of 52%<0.01
Strong windRelatively Moderate16th1.6 of 52%0.28
HailVery Low11th1.4 of 59%0.05
TornadoVery Low4th1.2 of 5<1%0.10
LightningVery Low0th1.0 of 5<1%11.3
HurricaneVery Low0th1.0 of 5<1%0.02
Winter weatherVery Low0th1.0 of 5<1%<0.01

Perils not assessed in Imperial County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county
Ice stormFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 1.4 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.6 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 130 MW solar array

At an assumed replacement value of $0.90 per watt, or $117.0M insured, the modeled expected annual loss for a fixed tilt ground mount array in Imperial County is $22,992 a year, $177 per MW, 0.02% of insured value.

Heat is modeled as a production risk rather than a property loss: 2.1% of annual yield in this county.

Insurability signal: Standard. Earthquake carries 58% of modeled loss.

Model hail, wind and flood exposure for Imperial County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.