MOJAVE SOLAR PROJECT

Operating

Solar power plant

Capacity
280 MW
Primary fuel
Solar
County
San Bernardino County
Operator
MOJAVE SOLAR LLC
Status
Operating
Commissioned
2014
EIA plant ID
57331
Generators
2
Technology
Solar Thermal without Energy Storage
Net generation (2024)
629 GWh
Capacity factor (2024, EIA nameplate)
26%
Data vintage
EIA-860 2024 final; EIA-923 2022-2024 final
Coordinates
35.0111, -117.3236

See it on the map

MOJAVE SOLAR PROJECT, a 280 MW Solar power plant in San Bernardino County, California. Operated by MOJAVE SOLAR LLC, commissioned 2014.

How MOJAVE SOLAR PROJECT compares

With 280 MW of capacity, MOJAVE SOLAR PROJECT ranks 55th among the 874 operating power plants Bywatts maps in California and 6th of the 303 operating Solar plants in the state. It accounts for about 3.8% of California's operating Solar capacity and 0.4% of all operating capacity in the state. Nationally it is the 8th-largest of the 639 operating Solar plants in the database. Commissioned in 2014, it is newer than 80% of the 859 operating California plants with a recorded commissioning year. It shares San Bernardino County with 64 other operating plants, including MOUNTAINVIEW GENERATING STATION and HIGH DESERT POWER PLANT.

EIA-860 lists 2 generators at the site with 280 MW of nameplate capacity, all solar thermal without energy storage technology. Net generation was 629 GWh in 2024 (a 26% capacity factor), up 6% from 2022.

Grid neighborhood

The nearest named substation is SANDLOT, about 1.5 miles away; the closest transmission line found within 10 miles is a 230 kV line owned by AZUSA LIGHT & POWER, about 1.0 miles away. Another 8 operating power plants totaling 151 MW sit within 25 miles; the largest is SEGS VIII (92 MW, Solar).

Computed by Bywatts from HIFLD power plant, substation and transmission line records and EIA-860/923 survey data; distances are straight-line. Sources and methodology

Weather peril exposure

MOJAVE SOLAR PROJECT is a 280 MW solar power plant in San Bernardino County, CA, operated by MOJAVE SOLAR LLC, commissioned in 2014. San Bernardino County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 2.3 of 5 at the 33rd national percentile. Earthquake is the leading peril, rated Very High by FEMA at the 99th percentile.

2.3 of 5Modeled catastrophe exposure
ModerateExposure band
EarthquakeLeading peril
StandardInsurability signal

San Bernardino County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
EarthquakeVery High99th5.0 of 518%0.11
WildfireVery High99th4.9 of 543%<0.01
Riverine floodingVery High97th4.9 of 522%13.0
Heat waveRelatively High43rd2.7 of 5<1%11.6
HailRelatively Moderate20th1.8 of 515%0.07
Strong windRelatively High10th1.4 of 51%0.18
TornadoRelatively Moderate10th1.4 of 51%0.76
LightningRelatively High3rd1.1 of 5<1%16.8
Winter weatherRelatively Low1st1.0 of 5<1%2.1

Perils not assessed in San Bernardino County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "No Rating" for this county
Coastal floodingFEMA rating is "Not Applicable" for this county
Ice stormFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 1.8 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.4 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 280 MW solar array

At an assumed replacement value of $0.90 per watt, or $252.0M insured, the modeled expected annual loss for a fixed tilt ground mount array in San Bernardino County is $128,997 a year, $461 per MW, 0.05% of insured value.

Heat is modeled as a production risk rather than a property loss: 1.3% of annual yield in this county.

Insurability signal: Standard. Wildfire carries 43% of modeled loss.

Model hail, wind and flood exposure for San Bernardino County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.