DOE GOLDEN NWTC LOAD SIDE

Operating

Solar power plant

Capacity
1 MW
Primary fuel
Solar
County
Jefferson County
Operator
DOE NATIONAL RENEWABLE ENERGY LABORATORY
Status
Operating
EIA plant ID
57692
Coordinates
39.9092, -105.2320

See it on the map

DOE GOLDEN NWTC LOAD SIDE, a 1 MW Solar power plant in Jefferson County, Colorado. Operated by DOE NATIONAL RENEWABLE ENERGY LABORATORY.

Weather peril exposure

DOE GOLDEN NWTC LOAD SIDE is a 1 MW solar power plant in Jefferson County, CO, operated by DOE NATIONAL RENEWABLE ENERGY LABORATORY. Jefferson County carries critical modeled catastrophe exposure in the FEMA National Risk Index, scoring 5.0 of 5 at the 99th national percentile. Hail is the leading peril, rated Very High by FEMA at the 99th percentile.

5.0 of 5Modeled catastrophe exposure
CriticalExposure band
HailLeading peril
DifficultInsurability signal

Jefferson County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
HailVery High99th5.0 of 597%6.9
WildfireRelatively High97th4.9 of 51%<0.01
Winter weatherVery High67th3.7 of 5<1%18.9
TornadoRelatively High66th3.7 of 51%0.56
EarthquakeRelatively Low47th2.9 of 5<1%<0.01
Riverine floodingRelatively High27th2.1 of 5<1%1.3
LightningVery High26th2.0 of 5<1%57.7
Heat waveRelatively Low26th2.0 of 5<1%0.18
Strong windRelatively High26th2.0 of 5<1%0.95
Ice stormRelatively Moderate2nd1.1 of 5<1%0.01

Perils not assessed in Jefferson County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "Not Applicable" for this county
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 5.0 of 5, which sits in the 10% to 15% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 3.7 of 5, indicating a 2% to 5% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 10% to 15% of insured value. Wind deductible range: 2% to 5%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 1 MW solar array

At an assumed replacement value of $0.90 per watt, or $900,000 insured, the modeled expected annual loss for a fixed tilt ground mount array in Jefferson County is $9,321 a year, $9,321 per MW, 1.04% of insured value.

Heat is modeled as a production risk rather than a property loss: 0.8% of annual yield in this county.

Insurability signal: Difficult. Hail at 5.0 of 5. Named windstorm and severe wind at 3.7 of 5.

Model hail, wind and flood exposure for Jefferson County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.