SAN LUIS VALLEY SOLAR RANCH

Operating

Solar power plant

Capacity
35 MW
Primary fuel
Solar
County
Alamosa County
Operator
IBERDROLA RENEWABLES INC
Status
Operating
Commissioned
2011
EIA plant ID
57317
Coordinates
37.6944, -105.9277

See it on the map

SAN LUIS VALLEY SOLAR RANCH, a 35 MW Solar power plant in Alamosa County, Colorado. Operated by IBERDROLA RENEWABLES INC, commissioned 2011.

Weather peril exposure

SAN LUIS VALLEY SOLAR RANCH is a 35 MW solar power plant in Alamosa County, CO, operated by IBERDROLA RENEWABLES INC, commissioned in 2011. Alamosa County carries low modeled catastrophe exposure in the FEMA National Risk Index, scoring 1.7 of 5 at the 17th national percentile. Earthquake is the leading peril, rated Relatively Low by FEMA at the 84th percentile.

1.7 of 5Modeled catastrophe exposure
LowExposure band
EarthquakeLeading peril
StandardInsurability signal

Alamosa County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
EarthquakeRelatively Low84th4.3 of 52%<0.01
WildfireVery Low42nd2.7 of 51%<0.01
HailRelatively Low38th2.5 of 587%0.79
Winter weatherRelatively Low21st1.8 of 5<1%6.1
Ice stormVery Low17th1.7 of 5<1%0.01
Heat waveVery Low16th1.6 of 5<1%0.34
TornadoVery Low15th1.6 of 52%0.05
LightningRelatively Moderate10th1.4 of 5<1%57.7
Riverine floodingRelatively Low4th1.2 of 57%0.07
Strong windVery Low3rd1.1 of 5<1%0.06

Perils not assessed in Alamosa County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "Not Applicable" for this county
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 2.5 of 5, which sits in the 2% to 5% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.6 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 2% to 5% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 35 MW solar array

At an assumed replacement value of $0.90 per watt, or $31.5M insured, the modeled expected annual loss for a fixed tilt ground mount array in Alamosa County is $9,212 a year, $263 per MW, 0.03% of insured value.

Heat is modeled as a production risk rather than a property loss: 0.5% of annual yield in this county.

Insurability signal: Standard. Hail carries 87% of modeled loss.

Model hail, wind and flood exposure for Alamosa County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.