UPSON ROCKY CREEK SOLAR PLANT

Operating

Solar power plant

Capacity
1 MW
Primary fuel
Solar
County
Upson County
Operator
SDD SOLAR PROJECT 4, LLC
Status
Operating
Commissioned
2012
EIA plant ID
58485
Coordinates
32.9208, -84.3431

See it on the map

UPSON ROCKY CREEK SOLAR PLANT, a 1 MW Solar power plant in Upson County, Georgia. Operated by SDD SOLAR PROJECT 4, LLC, commissioned 2012.

Weather peril exposure

UPSON ROCKY CREEK SOLAR PLANT is a 1 MW solar power plant in Upson County, GA, operated by SDD SOLAR PROJECT 4, LLC, commissioned in 2012. Upson County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 2.5 of 5 at the 37th national percentile. Lightning is the leading peril, rated Relatively Low by FEMA at the 97th percentile.

2.5 of 5Modeled catastrophe exposure
ModerateExposure band
LightningLeading peril
StandardInsurability signal

Upson County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
LightningRelatively Low97th4.9 of 52%63.2
HurricaneRelatively Low66th3.6 of 57%0.06
EarthquakeVery Low57th3.3 of 5<1%<0.01
HailRelatively Low50th3.0 of 576%3.5
WildfireVery Low47th2.9 of 5<1%<0.01
Strong windRelatively Low46th2.8 of 53%1.9
TornadoRelatively Low38th2.5 of 56%0.22
Ice stormVery Low35th2.4 of 5<1%0.47
Heat waveRelatively Low30th2.2 of 5<1%5.3
Winter weatherVery Low24th1.9 of 5<1%0.89
Riverine floodingVery Low20th1.8 of 55%0.93

Perils not assessed in Upson County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 3.0 of 5, which sits in the 2% to 5% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 3.6 of 5, indicating a 2% to 5% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 2% to 5% of insured value. Wind deductible range: 2% to 5%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 1 MW solar array

At an assumed replacement value of $0.90 per watt, or $900,000 insured, the modeled expected annual loss for a fixed tilt ground mount array in Upson County is $524 a year, $524 per MW, 0.06% of insured value.

Heat is modeled as a production risk rather than a property loss: 0.9% of annual yield in this county.

Insurability signal: Standard. Named windstorm and severe wind at 3.6 of 5.

Model hail, wind and flood exposure for Upson County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.