NEVADA SOLAR ONE

Operating

Solar power plant

Capacity
76 MW
Primary fuel
Solar
County
Clark County
Operator
ACCIONA SOLAR POWER
Status
Operating
Commissioned
2007
EIA plant ID
56405
Generators
1
Technology
Solar Thermal without Energy Storage
Net generation (2024)
92.4 GWh
Capacity factor (2024, EIA nameplate)
14%
Data vintage
EIA-860 2024 final; EIA-923 2022-2024 final
Coordinates
35.7998, -114.9817

See it on the map

NEVADA SOLAR ONE, a 76 MW Solar power plant in Clark County, Nevada. Operated by ACCIONA SOLAR POWER, commissioned 2007.

How NEVADA SOLAR ONE compares

With 76 MW of capacity, NEVADA SOLAR ONE ranks 25th among the 50 operating power plants Bywatts maps in Nevada and 7th of the 17 operating Solar plants in the state. It accounts for about 5.5% of Nevada's operating Solar capacity and 0.6% of all operating capacity in the state. Nationally it is the 38th-largest of the 639 operating Solar plants in the database. Commissioned in 2007, it is newer than 44% of the 49 operating Nevada plants with a recorded commissioning year. It shares Clark County with 28 other operating plants, including CHUCK LENZIE GENERATING STATION and CLARK (NVE).

EIA-860 lists 1 generator at the site with 76 MW of nameplate capacity, all solar thermal without energy storage technology. Net generation was 92.4 GWh in 2024 (a 14% capacity factor), down 1% from 2022.

Grid neighborhood

The nearest named substation is NEVADA SOLAR ONE (230 kV), about 0.2 miles away; the closest transmission line found within 10 miles is a 230 kV line owned by NEVADA POWER COMPANY, about 0.2 miles away. Another 17 operating power plants totaling 5,675 MW sit within 25 miles; the largest is CLARK (NVE) (1,243 MW, Natural Gas). Within 50 miles are 2 mapped data centers; the nearest is Fiberhub LAS1 in Las Vegas, about 20.4 miles away.

Computed by Bywatts from HIFLD power plant, substation and transmission line records, EIA-860/923 survey data and PeeringDB data center locations; distances are straight-line. Sources and methodology

Weather peril exposure

NEVADA SOLAR ONE is a 76 MW solar power plant in Clark County, NV, operated by ACCIONA SOLAR POWER, commissioned in 2007. Clark County carries low modeled catastrophe exposure in the FEMA National Risk Index, scoring 1.7 of 5 at the 17th national percentile. Wildfire is the leading peril, rated Relatively High by FEMA at the 89th percentile.

1.7 of 5Modeled catastrophe exposure
LowExposure band
WildfireLeading peril
StandardInsurability signal

Clark County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
WildfireRelatively High89th4.6 of 516%<0.01
EarthquakeRelatively High88th4.5 of 54%0.02
Riverine floodingVery High48th2.9 of 514%7.3
HailRelatively High33rd2.3 of 566%0.12
Heat waveVery High32nd2.3 of 5<1%11.8
LightningRelatively High14th1.6 of 5<1%24.3
Strong windRelatively Moderate3rd1.1 of 5<1%0.30
Winter weatherRelatively Moderate3rd1.1 of 5<1%2.2
TornadoVery Low1st1.0 of 5<1%0.17

Perils not assessed in Clark County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "No Rating" for this county
Coastal floodingFEMA rating is "Not Applicable" for this county
Ice stormFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 2.3 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.1 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 76 MW solar array

At an assumed replacement value of $0.90 per watt, or $68.4M insured, the modeled expected annual loss for a fixed tilt ground mount array in Clark County is $20,269 a year, $267 per MW, 0.03% of insured value.

Heat is modeled as a production risk rather than a property loss: 1.0% of annual yield in this county.

Insurability signal: Standard. Hail carries 66% of modeled loss.

Model hail, wind and flood exposure for Clark County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.