CIMARRON SOLAR FACILITY

Operating

Solar power plant

Capacity
31 MW
Primary fuel
Solar
County
Colfax County
Operator
FIRST SOLAR ENERGY LLC
Status
Operating
Commissioned
2010
EIA plant ID
57243
Coordinates
36.4681, -104.6357

See it on the map

CIMARRON SOLAR FACILITY, a 31 MW Solar power plant in Colfax County, New Mexico. Operated by FIRST SOLAR ENERGY LLC, commissioned 2010.

Weather peril exposure

CIMARRON SOLAR FACILITY is a 31 MW solar power plant in Colfax County, NM, operated by FIRST SOLAR ENERGY LLC, commissioned in 2010. Colfax County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 2.5 of 5 at the 39th national percentile. Wildfire is the leading peril, rated Relatively Moderate by FEMA at the 96th percentile.

2.5 of 5Modeled catastrophe exposure
ModerateExposure band
WildfireLeading peril
StandardInsurability signal

Colfax County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
WildfireRelatively Moderate96th4.9 of 522%<0.01
Winter weatherRelatively High75th4.0 of 51%20.3
Riverine floodingRelatively Low75th4.0 of 59%1.2
HailRelatively Low47th2.9 of 566%1.3
EarthquakeVery Low34th2.4 of 5<1%<0.01
Strong windRelatively Low17th1.7 of 51%0.18
TornadoVery Low15th1.6 of 51%0.40
LightningRelatively High10th1.4 of 5<1%68.5
Heat waveVery Low9th1.4 of 5<1%0.04
Ice stormVery Low2nd1.1 of 5<1%0.01

Perils not assessed in Colfax County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "Not Applicable" for this county
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 2.9 of 5, which sits in the 2% to 5% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.7 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 2% to 5% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 31 MW solar array

At an assumed replacement value of $0.90 per watt, or $27.9M insured, the modeled expected annual loss for a fixed tilt ground mount array in Colfax County is $16,795 a year, $542 per MW, 0.06% of insured value.

Heat is modeled as a production risk rather than a property loss: 0.3% of annual yield in this county.

Insurability signal: Standard. Hail carries 66% of modeled loss.

Model hail, wind and flood exposure for Colfax County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.