LAS VEGAS SOLAR ENERGY CENTER

Operating

Solar power plant

Capacity
5 MW
Primary fuel
Solar
County
San Miguel County
Operator
FIRST SOLAR ENERGY LLC
Status
Operating
Commissioned
2011
EIA plant ID
57576
Coordinates
35.6433, -105.2067

See it on the map

LAS VEGAS SOLAR ENERGY CENTER, a 5 MW Solar power plant in San Miguel County, New Mexico. Operated by FIRST SOLAR ENERGY LLC, commissioned 2011.

Weather peril exposure

LAS VEGAS SOLAR ENERGY CENTER is a 5 MW solar power plant in San Miguel County, NM, operated by FIRST SOLAR ENERGY LLC, commissioned in 2011. San Miguel County carries low modeled catastrophe exposure in the FEMA National Risk Index, scoring 1.6 of 5 at the 15th national percentile. Wildfire is the leading peril, rated Relatively Moderate by FEMA at the 95th percentile.

1.6 of 5Modeled catastrophe exposure
LowExposure band
WildfireLeading peril
StandardInsurability signal

San Miguel County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
WildfireRelatively Moderate95th4.8 of 533%<0.01
Riverine floodingRelatively Moderate93rd4.7 of 531%1.6
Winter weatherRelatively Moderate74th4.0 of 52%15.2
EarthquakeVery Low42nd2.7 of 5<1%<0.01
HailRelatively Low19th1.8 of 529%1.3
Strong windRelatively Low18th1.7 of 52%0.29
TornadoVery Low15th1.6 of 52%0.44
Heat waveVery Low11th1.5 of 5<1%0.37
LightningRelatively Moderate6th1.3 of 5<1%62.4
Ice stormVery Low4th1.2 of 5<1%0.11

Perils not assessed in San Miguel County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "Not Applicable" for this county
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 1.8 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.7 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 5 MW solar array

At an assumed replacement value of $0.90 per watt, or $4.5M insured, the modeled expected annual loss for a fixed tilt ground mount array in San Miguel County is $1,218 a year, $244 per MW, 0.03% of insured value.

Heat is modeled as a production risk rather than a property loss: 0.3% of annual yield in this county.

Insurability signal: Standard. Wildfire carries 33% of modeled loss.

Model hail, wind and flood exposure for San Miguel County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.