SILVER CITY WWTP PV PROJECT

Operating

Solar power plant

Capacity
1 MW
Primary fuel
Solar
County
Grant County
Operator
AFFORDABLE SOLAR SILVER CITY LLC
Status
Operating
Commissioned
2013
EIA plant ID
58540
Coordinates
32.7139, -108.2481

See it on the map

SILVER CITY WWTP PV PROJECT, a 1 MW Solar power plant in Grant County, New Mexico. Operated by AFFORDABLE SOLAR SILVER CITY LLC, commissioned 2013.

Weather peril exposure

SILVER CITY WWTP PV PROJECT is a 1 MW solar power plant in Grant County, NM, operated by AFFORDABLE SOLAR SILVER CITY LLC, commissioned in 2013. Grant County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 1.8 of 5 at the 20th national percentile. Wildfire is the leading peril, rated Relatively Moderate by FEMA at the 95th percentile.

1.8 of 5Modeled catastrophe exposure
ModerateExposure band
WildfireLeading peril
StandardInsurability signal

Grant County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
WildfireRelatively Moderate95th4.8 of 531%<0.01
Riverine floodingRelatively Moderate94th4.8 of 527%2.0
EarthquakeVery Low40th2.6 of 5<1%<0.01
Heat waveRelatively Low29th2.2 of 5<1%1.5
HailVery Low27th2.1 of 541%0.14
Winter weatherRelatively Moderate22nd1.9 of 5<1%7.4
LightningRelatively Moderate7th1.3 of 5<1%65.2
Strong windVery Low4th1.2 of 5<1%0.14
Ice stormVery Low4th1.2 of 5<1%0.01
TornadoVery Low3rd1.1 of 5<1%0.05
HurricaneVery Low2nd1.1 of 5<1%<0.01

Perils not assessed in Grant County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 2.1 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.2 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 1 MW solar array

At an assumed replacement value of $0.90 per watt, or $900,000 insured, the modeled expected annual loss for a fixed tilt ground mount array in Grant County is $303 a year, $303 per MW, 0.03% of insured value.

Heat is modeled as a production risk rather than a property loss: 0.9% of annual yield in this county.

Insurability signal: Standard. Hail carries 41% of modeled loss.

Model hail, wind and flood exposure for Grant County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.