SPS5 HOPI

Operating

Solar power plant

Capacity
10 MW
Primary fuel
Solar
County
Eddy County
Operator
SUNE SPS5, LLC
Status
Operating
Commissioned
2011
EIA plant ID
57740
Coordinates
32.6818, -103.3011

See it on the map

SPS5 HOPI, a 10 MW Solar power plant in Eddy County, New Mexico. Operated by SUNE SPS5, LLC, commissioned 2011.

Weather peril exposure

SPS5 HOPI is a 10 MW solar power plant in Eddy County, NM, operated by SUNE SPS5, LLC, commissioned in 2011. Eddy County carries elevated modeled catastrophe exposure in the FEMA National Risk Index, scoring 3.1 of 5 at the 52nd national percentile. Riverine flooding is the leading peril, rated Relatively Moderate by FEMA at the 98th percentile.

3.1 of 5Modeled catastrophe exposure
ElevatedExposure band
Riverine floodingLeading peril
StandardInsurability signal

Eddy County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
Riverine floodingRelatively Moderate98th4.9 of 514%4.6
Ice stormRelatively High83rd4.3 of 53%0.45
WildfireRelatively Low80th4.2 of 52%<0.01
Winter weatherRelatively High79th4.2 of 51%6.5
Heat waveRelatively Low64th3.6 of 5<1%4.9
HailRelatively Moderate60th3.4 of 576%1.6
LightningRelatively Moderate47th2.9 of 5<1%48.1
Strong windRelatively Moderate30th2.2 of 51%0.60
TornadoRelatively Low23rd1.9 of 52%0.74
HurricaneVery Low13th1.5 of 5<1%<0.01
EarthquakeVery Low11th1.5 of 5<1%<0.01

Perils not assessed in Eddy County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 3.4 of 5, which sits in the 2% to 5% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 2.2 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 2% to 5% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 10 MW solar array

At an assumed replacement value of $0.90 per watt, or $9.1M insured, the modeled expected annual loss for a fixed tilt ground mount array in Eddy County is $8,040 a year, $796 per MW, 0.09% of insured value.

Heat is modeled as a production risk rather than a property loss: 1.9% of annual yield in this county.

Insurability signal: Standard. Hail carries 76% of modeled loss.

Model hail, wind and flood exposure for Eddy County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.