SUNE EPE2 LLC

Operating

Solar power plant

Capacity
14 MW
Primary fuel
Solar
County
Doña Ana County
Operator
SUNE EPE2 LLC
Status
Operating
Commissioned
2012
EIA plant ID
57985
Coordinates
32.2517, -106.9133

See it on the map

SUNE EPE2 LLC, a 14 MW Solar power plant in Doña Ana County, New Mexico. Operated by SUNE EPE2 LLC, commissioned 2012.

Weather peril exposure

SUNE EPE2 LLC is a 14 MW solar power plant in Doña Ana County, NM, operated by SUNE EPE2 LLC, commissioned in 2012. Doña Ana County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 2.5 of 5 at the 37th national percentile. Riverine flooding is the leading peril, rated Relatively High by FEMA at the 85th percentile.

2.5 of 5Modeled catastrophe exposure
ModerateExposure band
Riverine floodingLeading peril
StandardInsurability signal

Doña Ana County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
Riverine floodingRelatively High85th4.4 of 511%2.5
EarthquakeRelatively Moderate65th3.6 of 5<1%<0.01
Heat waveRelatively Moderate64th3.6 of 5<1%4.4
Winter weatherVery High58th3.3 of 5<1%2.4
WildfireRelatively Low55th3.2 of 51%<0.01
LightningVery High54th3.1 of 5<1%52.1
HailRelatively High52nd3.1 of 586%0.41
Ice stormRelatively Moderate24th1.9 of 5<1%0.04
Strong windRelatively Moderate8th1.3 of 5<1%0.36
HurricaneVery Low5th1.2 of 5<1%<0.01
TornadoVery Low3rd1.1 of 5<1%0.13

Perils not assessed in Doña Ana County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 3.1 of 5, which sits in the 2% to 5% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.3 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 2% to 5% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 14 MW solar array

At an assumed replacement value of $0.90 per watt, or $12.6M insured, the modeled expected annual loss for a fixed tilt ground mount array in Doña Ana County is $7,219 a year, $516 per MW, 0.06% of insured value.

Heat is modeled as a production risk rather than a property loss: 1.9% of annual yield in this county.

Insurability signal: Standard. Hail carries 86% of modeled loss.

Model hail, wind and flood exposure for Doña Ana County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.