BRYAN SOLAR FIELD

Operating

Solar power plant

Capacity
2 MW
Primary fuel
Solar
County
Williams County
Operator
CITY OF BRYAN - (OH)
Status
Operating
Commissioned
2012
EIA plant ID
58381
Coordinates
41.4764, -84.5861

See it on the map

BRYAN SOLAR FIELD, a 2 MW Solar power plant in Williams County, Ohio. Operated by CITY OF BRYAN - (OH), commissioned 2012.

Weather peril exposure

BRYAN SOLAR FIELD is a 2 MW solar power plant in Williams County, OH, operated by CITY OF BRYAN - (OH), commissioned in 2012. Williams County carries high modeled catastrophe exposure in the FEMA National Risk Index, scoring 3.6 of 5 at the 65th national percentile. Heat wave is the leading peril, rated Very Low by FEMA at the 84th percentile.

3.6 of 5Modeled catastrophe exposure
HighExposure band
Heat waveLeading peril
ConstrainedInsurability signal

Williams County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
Heat waveVery Low84th4.3 of 5<1%4.0
TornadoRelatively Moderate79th4.2 of 58%0.21
Strong windRelatively Moderate71st3.8 of 54%5.1
HailRelatively Moderate70th3.8 of 585%3.3
Ice stormRelatively Moderate63rd3.5 of 51%1.6
EarthquakeRelatively Low57th3.3 of 5<1%<0.01
Winter weatherRelatively Low42nd2.7 of 5<1%10.6
LightningRelatively Low40th2.6 of 5<1%38.3
HurricaneVery Low22nd1.9 of 5<1%<0.01
Riverine floodingRelatively Low21st1.8 of 52%0.21
WildfireVery Low1st1.0 of 5<1%<0.01

Perils not assessed in Williams County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 3.8 of 5, which sits in the 5% to 10% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 4.2 of 5, indicating a 2% to 5% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 5% to 10% of insured value. Wind deductible range: 2% to 5%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 2 MW solar array

At an assumed replacement value of $0.90 per watt, or $1.9M insured, the modeled expected annual loss for a fixed tilt ground mount array in Williams County is $2,384 a year, $1,135 per MW, 0.13% of insured value.

Heat is modeled as a production risk rather than a property loss: 2.5% of annual yield in this county.

Insurability signal: Constrained. Hail at 3.8 of 5. Named windstorm and severe wind at 4.2 of 5.

Model hail, wind and flood exposure for Williams County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.