GRAHAM

Operating

Natural Gas power plant

Capacity
635 MW
Primary fuel
Natural Gas
County
Young County
Operator
LUMINANT GENERATION COMPANY LLC
Status
Operating
Commissioned
1960
EIA plant ID
3490
Generators
2
Technology
Natural Gas Steam Turbine
Net generation (2024)
1,042 GWh
Capacity factor (2024, EIA nameplate)
19%
Data vintage
EIA-860 2024 final; EIA-923 2022-2024 final
Coordinates
33.1352, -98.6116

See it on the map

GRAHAM, a 635 MW Natural Gas power plant in Young County, Texas. Operated by LUMINANT GENERATION COMPANY LLC, commissioned 1960.

How GRAHAM compares

With 635 MW of capacity, GRAHAM ranks 59th among the 307 operating power plants Bywatts maps in Texas and 45th of the 134 operating Natural Gas plants in the state. It accounts for about 0.9% of Texas's operating Natural Gas capacity and 0.6% of all operating capacity in the state. Nationally it is the 240th-largest of the 1,185 operating Natural Gas plants in the database. Commissioned in 1960, it is older than 91% of the 303 operating Texas plants with a recorded commissioning year. Its operator, LUMINANT GENERATION COMPANY LLC, runs 9 operating plants in Texas totaling 9,469 MW. It shares Young County with one other operating plant, TRINITY HILLS.

EIA-860 lists 2 generators at the site with 635 MW of nameplate capacity, all natural gas steam turbine technology. Net generation was 1,042 GWh in 2024 (a 19% capacity factor). Its generators came online between 1960 and 1969.

Grid neighborhood

The closest transmission line found within 10 miles is a 138 kV line owned by ONCOR ELECTRIC DELIVERY CO., under 0.1 miles away. Another 3 operating power plants totaling 525 MW sit within 25 miles; the largest is TRINITY HILLS (225 MW, Wind).

Computed by Bywatts from HIFLD power plant and transmission line records and EIA-860/923 survey data; distances are straight-line. Sources and methodology

Weather peril exposure

GRAHAM is a 635 MW natural gas power plant in Young County, TX, operated by LUMINANT GENERATION COMPANY LLC, commissioned in 1960. Young County carries high modeled catastrophe exposure in the FEMA National Risk Index, scoring 4.1 of 5 at the 78th national percentile. Strong wind is the leading peril, rated Relatively Moderate by FEMA at the 89th percentile.

The Bywatts loss layer is calibrated to solar PV hardware, so it is not applied to a natural gas plant. The ratings below are the FEMA National Risk Index county hazard ratings for this location.

4.1 of 5Modeled catastrophe exposure
HighExposure band
Strong windLeading peril
Very LowFEMA county risk rating

Young County hazard ratings

PerilFEMA ratingNational percentilePeril scoreEvents per year
Strong windRelatively Moderate89th4.5 of 52.4
WildfireRelatively Moderate88th4.5 of 5<0.01
HailRelatively Moderate81st4.2 of 57.4
TornadoRelatively Low64th3.6 of 50.66
Heat waveRelatively Low51st3.1 of 512.3
LightningVery Low44th2.8 of 548.8
HurricaneVery Low43rd2.7 of 50.01
Winter weatherRelatively Low38th2.5 of 55.1
Ice stormRelatively Low26th2.0 of 50.78
EarthquakeVery Low22nd1.9 of 5<0.01
Riverine floodingVery Low20th1.8 of 51.1

Perils not assessed in Young County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Model hail, wind and flood exposure for Young County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level.