CALIFORNIA PV ENERGY AT ISD WWTP

Operating

Solar power plant

Capacity
1 MW
Primary fuel
Solar
County
Contra Costa County
Operator
CALIFORNIA PV ENERGY LLC
Status
Operating
Commissioned
2014
EIA plant ID
59283
Coordinates
38.0011, -121.7039

See it on the map

CALIFORNIA PV ENERGY AT ISD WWTP, a 1 MW Solar power plant in Contra Costa County, California. Operated by CALIFORNIA PV ENERGY LLC, commissioned 2014.

Weather peril exposure

CALIFORNIA PV ENERGY AT ISD WWTP is a 1 MW solar power plant in Contra Costa County, CA, operated by CALIFORNIA PV ENERGY LLC, commissioned in 2014. Contra Costa County carries low modeled catastrophe exposure in the FEMA National Risk Index, scoring 1.5 of 5 at the 13th national percentile. Earthquake is the leading peril, rated Relatively High by FEMA at the 99th percentile.

1.5 of 5Modeled catastrophe exposure
LowExposure band
EarthquakeLeading peril
StandardInsurability signal

Contra Costa County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
EarthquakeRelatively High99th5.0 of 537%0.13
Riverine floodingVery High93rd4.7 of 534%1.2
WildfireRelatively Moderate91st4.6 of 523%<0.01
Heat waveRelatively High45th2.8 of 5<1%8.5
Coastal floodingRelatively Moderate41st2.6 of 52%1.5
TornadoRelatively Low9th1.4 of 51%0.10
HailVery Low4th1.2 of 52%0.04
Strong windRelatively Low2nd1.1 of 5<1%0.04
LightningRelatively High2nd1.1 of 5<1%4.5
Winter weatherVery Low1st1.0 of 5<1%0.44

Perils not assessed in Contra Costa County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "Not Applicable" for this county
Ice stormFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 1.2 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.4 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 1 MW solar array

At an assumed replacement value of $0.90 per watt, or $900,000 insured, the modeled expected annual loss for a fixed tilt ground mount array in Contra Costa County is $222 a year, $222 per MW, 0.02% of insured value.

Heat is modeled as a production risk rather than a property loss: 1.4% of annual yield in this county.

Insurability signal: Standard. Earthquake carries 37% of modeled loss.

Model hail, wind and flood exposure for Contra Costa County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.