RATHDRUM POWER LLC

Operating

Natural Gas power plant

Capacity
302 MW
Primary fuel
Natural Gas
County
Kootenai County
Operator
RATHDRUM OPERATING SERVICES CO., INC.
Status
Operating
Commissioned
2001
EIA plant ID
55179
Generators
2
Technology
Natural Gas Fired Combined Cycle
Net generation (2024)
1,373 GWh
Capacity factor (2024, EIA nameplate)
52%
Data vintage
EIA-860 2024 final; EIA-923 2022-2024 final
Coordinates
47.8043, -116.8672

See it on the map

RATHDRUM POWER LLC, a 302 MW Natural Gas power plant in Kootenai County, Idaho. Operated by RATHDRUM OPERATING SERVICES CO., INC., commissioned 2001.

How RATHDRUM POWER LLC compares

With 302 MW of capacity, RATHDRUM POWER LLC ranks 4th among the 123 operating power plants Bywatts maps in Idaho and is the largest of the 4 operating Natural Gas plants in the state. It accounts for about 33% of Idaho's operating Natural Gas capacity and 6.1% of all operating capacity in the state. Nationally it is the 455th-largest of the 1,185 operating Natural Gas plants in the database. Commissioned in 2001, it is newer than 61% of the 121 operating Idaho plants with a recorded commissioning year. It shares Kootenai County with 3 other operating plants, including RATHDRUM and POST FALLS.

EIA-860 lists 2 generators at the site with 302 MW of nameplate capacity, all natural gas fired combined cycle technology. Net generation was 1,373 GWh in 2024 (a 52% capacity factor), down 17% from 2022.

Grid neighborhood

The nearest named substation is RATHDRUM (230 kV), about 0.1 miles away; the closest transmission line found within 10 miles is a 230 kV line owned by AVISTA CORP, under 0.1 miles away. Another 6 operating power plants totaling 288 MW sit within 25 miles; the largest is RATHDRUM (166 MW, Natural Gas). Within 50 miles are 2 mapped data centers; the nearest is TierPoint Spokane in Liberty Lake, about 13.9 miles away.

Computed by Bywatts from HIFLD power plant, substation and transmission line records, EIA-860/923 survey data and PeeringDB data center locations; distances are straight-line. Sources and methodology

Weather peril exposure

RATHDRUM POWER LLC is a 302 MW natural gas power plant in Kootenai County, ID, operated by RATHDRUM OPERATING SERVICES CO., INC., commissioned in 2001. Kootenai County carries low modeled catastrophe exposure in the FEMA National Risk Index, scoring 1.0 of 5 at the 1st national percentile. Wildfire is the leading peril, rated Relatively Low by FEMA at the 62nd percentile.

The Bywatts loss layer is calibrated to solar PV hardware, so it is not applied to a natural gas plant. The ratings below are the FEMA National Risk Index county hazard ratings for this location.

1.0 of 5Modeled catastrophe exposure
LowExposure band
WildfireLeading peril
Relatively LowFEMA county risk rating

Kootenai County hazard ratings

PerilFEMA ratingNational percentilePeril scoreEvents per year
WildfireRelatively Low62nd3.5 of 5<0.01
EarthquakeRelatively Low60th3.4 of 5<0.01
Heat waveRelatively Moderate59th3.4 of 53.3
Riverine floodingRelatively Moderate49th2.9 of 51.2
Winter weatherRelatively High44th2.8 of 526.8
Ice stormRelatively High15th1.6 of 50.25
Strong windRelatively Low11th1.5 of 50.24
LightningRelatively Low7th1.3 of 517.9
HailVery Low6th1.3 of 50.26
TornadoVery Low6th1.2 of 50.04

Perils not assessed in Kootenai County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "Not Applicable" for this county
Coastal floodingFEMA rating is "Not Applicable" for this county

Model hail, wind and flood exposure for Kootenai County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level.