SHORE POINT SOLAR

Operating

Solar power plant

Capacity
1 MW
Primary fuel
Solar
County
Monmouth County
Operator
SHORE POINT SOLAR LLC
Status
Operating
Commissioned
2011
EIA plant ID
57951
Coordinates
40.2452, -74.2435

See it on the map

SHORE POINT SOLAR, a 1 MW Solar power plant in Monmouth County, New Jersey. Operated by SHORE POINT SOLAR LLC, commissioned 2011.

Weather peril exposure

SHORE POINT SOLAR is a 1 MW solar power plant in Monmouth County, NJ, operated by SHORE POINT SOLAR LLC, commissioned in 2011. Monmouth County carries elevated modeled catastrophe exposure in the FEMA National Risk Index, scoring 2.8 of 5 at the 46th national percentile. Strong wind is the leading peril, rated Very High by FEMA at the 100th percentile.

2.8 of 5Modeled catastrophe exposure
ElevatedExposure band
Strong windLeading peril
ConstrainedInsurability signal

Monmouth County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
Strong windVery High100th5.0 of 571%5.8
HurricaneRelatively Moderate78th4.1 of 513%0.18
EarthquakeRelatively Moderate74th4.0 of 51%<0.01
Coastal floodingRelatively High71st3.9 of 57%3.7
Ice stormRelatively High60th3.4 of 51%0.70
WildfireRelatively Low59th3.4 of 51%<0.01
Winter weatherVery High40th2.6 of 5<1%9.2
Riverine floodingRelatively High28th2.1 of 54%3.5
LightningVery High24th2.0 of 5<1%31.5
TornadoRelatively Low13th1.5 of 51%0.21
HailVery Low7th1.3 of 51%1.9
Heat waveRelatively High1st1.1 of 5<1%6.7

Hail exposure and deductible structure

Hail scores 1.3 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 5.0 of 5, indicating a 5% to 10% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 5% to 10%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 1 MW solar array

At an assumed replacement value of $0.90 per watt, or $900,000 insured, the modeled expected annual loss for a fixed tilt ground mount array in Monmouth County is $668 a year, $668 per MW, 0.07% of insured value.

Heat is modeled as a production risk rather than a property loss: 0.0% of annual yield in this county.

Insurability signal: Constrained. Named windstorm and severe wind at 5.0 of 5.

Model hail, wind and flood exposure for Monmouth County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.