CHILDRESS KLEIN

Operating

Solar power plant

Capacity
2 MW
Primary fuel
Solar
County
Mecklenburg County
Operator
DUKE ENERGY CAROLINAS, LLC
Status
Operating
Commissioned
2010
EIA plant ID
57334
Coordinates
35.2454, -80.9967

See it on the map

CHILDRESS KLEIN, a 2 MW Solar power plant in Mecklenburg County, North Carolina. Operated by DUKE ENERGY CAROLINAS, LLC, commissioned 2010.

Weather peril exposure

CHILDRESS KLEIN is a 2 MW solar power plant in Mecklenburg County, NC, operated by DUKE ENERGY CAROLINAS, LLC, commissioned in 2010. Mecklenburg County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 2.0 of 5 at the 24th national percentile. Riverine flooding is the leading peril, rated Relatively High by FEMA at the 75th percentile.

2.0 of 5Modeled catastrophe exposure
ModerateExposure band
Riverine floodingLeading peril
StandardInsurability signal

Mecklenburg County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
Riverine floodingRelatively High75th4.0 of 514%3.5
EarthquakeRelatively Moderate61st3.4 of 51%<0.01
HurricaneRelatively Moderate57th3.3 of 54%0.09
Ice stormRelatively High49th2.9 of 51%2.1
HailRelatively High40th2.6 of 572%4.8
TornadoRelatively High33rd2.3 of 57%0.28
LightningRelatively High23rd1.9 of 5<1%52.1
Winter weatherRelatively High17th1.7 of 5<1%5.3
Heat waveRelatively Moderate12th1.5 of 5<1%3.0
WildfireVery Low10th1.4 of 5<1%<0.01
Strong windRelatively High3rd1.1 of 5<1%2.7

Perils not assessed in Mecklenburg County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 2.6 of 5, which sits in the 2% to 5% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 3.3 of 5, indicating a 1% to 2% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 2% to 5% of insured value. Wind deductible range: 1% to 2%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 2 MW solar array

At an assumed replacement value of $0.90 per watt, or $1.7M insured, the modeled expected annual loss for a fixed tilt ground mount array in Mecklenburg County is $663 a year, $349 per MW, 0.04% of insured value.

Heat is modeled as a production risk rather than a property loss: 0.3% of annual yield in this county.

Insurability signal: Standard. Hail carries 72% of modeled loss.

Model hail, wind and flood exposure for Mecklenburg County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.