MOCKSVILLE FARM

Operating

Solar power plant

Capacity
5 MW
Primary fuel
Solar
County
Davie County
Operator
MOCKSVILLE LESSEE LLC
Status
Operating
Commissioned
2012
EIA plant ID
58313
Coordinates
35.8786, -80.5419

See it on the map

MOCKSVILLE FARM, a 5 MW Solar power plant in Davie County, North Carolina. Operated by MOCKSVILLE LESSEE LLC, commissioned 2012.

Weather peril exposure

MOCKSVILLE FARM is a 5 MW solar power plant in Davie County, NC, operated by MOCKSVILLE LESSEE LLC, commissioned in 2012. Davie County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 1.8 of 5 at the 20th national percentile. Ice storm is the leading peril, rated Relatively High by FEMA at the 88th percentile.

1.8 of 5Modeled catastrophe exposure
ModerateExposure band
Ice stormLeading peril
StandardInsurability signal

Davie County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
Ice stormRelatively High88th4.5 of 513%2.0
HurricaneRelatively Low69th3.8 of 516%0.08
LightningRelatively Low60th3.4 of 51%49.7
Riverine floodingRelatively Low58th3.3 of 513%0.39
EarthquakeVery Low55th3.2 of 51%<0.01
TornadoRelatively Low30th2.2 of 57%0.10
HailRelatively Low28th2.1 of 546%5.0
Strong windRelatively Low25th2.0 of 52%2.4
WildfireVery Low24th1.9 of 5<1%<0.01
Heat waveVery Low13th1.5 of 5<1%1.4
Winter weatherRelatively Low8th1.3 of 5<1%7.1

Perils not assessed in Davie County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 2.1 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 3.8 of 5, indicating a 2% to 5% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 2% to 5%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 5 MW solar array

At an assumed replacement value of $0.90 per watt, or $4.5M insured, the modeled expected annual loss for a fixed tilt ground mount array in Davie County is $1,493 a year, $299 per MW, 0.03% of insured value.

Heat is modeled as a production risk rather than a property loss: 0.4% of annual yield in this county.

Insurability signal: Standard. Named windstorm and severe wind at 3.8 of 5.

Model hail, wind and flood exposure for Davie County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.