NEUSE RIVER SOLAR FARM
OperatingSolar power plant
- Capacity
- 1 MW
- Primary fuel
- Solar
- County
- Wake County
- Operator
- NRSF OPCO LLC
- Status
- Operating
- Commissioned
- 2011
- EIA plant ID
- 58524
- Coordinates
- 35.7145, -78.4997
NEUSE RIVER SOLAR FARM, a 1 MW Solar power plant in Wake County, North Carolina. Operated by NRSF OPCO LLC, commissioned 2011.
Weather peril exposure
NEUSE RIVER SOLAR FARM is a 1 MW solar power plant in Wake County, NC, operated by NRSF OPCO LLC, commissioned in 2011. Wake County carries high modeled catastrophe exposure in the FEMA National Risk Index, scoring 3.5 of 5 at the 62nd national percentile. Hail is the leading peril, rated Relatively High by FEMA at the 70th percentile.
Wake County hazard ratings
| Peril | FEMA rating | National percentile | Peril score | Share of modeled loss | Events per year |
|---|---|---|---|---|---|
| Hail | Relatively High | 70th | 3.8 of 5 | 89% | 4.1 |
| Hurricane | Relatively Moderate | 67th | 3.7 of 5 | 4% | 0.18 |
| Riverine flooding | Relatively High | 60th | 3.4 of 5 | 4% | 4.6 |
| Ice storm | Relatively High | 42nd | 2.7 of 5 | <1% | 1.6 |
| Earthquake | Relatively Low | 42nd | 2.7 of 5 | <1% | <0.01 |
| Tornado | Relatively High | 32nd | 2.3 of 5 | 2% | 0.41 |
| Winter weather | Relatively Moderate | 21st | 1.8 of 5 | <1% | 6.4 |
| Wildfire | Very Low | 16th | 1.7 of 5 | <1% | <0.01 |
| Heat wave | Relatively High | 15th | 1.6 of 5 | <1% | 6.9 |
| Lightning | Relatively High | 11th | 1.4 of 5 | <1% | 50.3 |
| Strong wind | Relatively Low | 4th | 1.2 of 5 | <1% | 0.94 |
Perils not assessed in Wake County
These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.
| Peril | Why it is not scored |
|---|---|
| Coastal flooding | FEMA rating is "Not Applicable" for this county |
Hail exposure and deductible structure
Hail scores 3.8 of 5, which sits in the 5% to 10% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 3.7 of 5, indicating a 2% to 5% wind deductible. Ranges, not single figures. The final structure is set by the carrier.
Percentage hail deductible range: 5% to 10% of insured value. Wind deductible range: 2% to 5%. These are the structures commonly seen at this exposure, not an offer and not a rate.
Modeled annual loss for a 1 MW solar array
At an assumed replacement value of $0.90 per watt, or $990,000 insured, the modeled expected annual loss for a fixed tilt ground mount array in Wake County is $1,162 a year, $1,056 per MW, 0.12% of insured value.
Heat is modeled as a production risk rather than a property loss: 0.5% of annual yield in this county.
Insurability signal: Constrained. Hail at 3.8 of 5. Named windstorm and severe wind at 3.7 of 5.
Model hail, wind and flood exposure for Wake County in the weather risk calculator
Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.
Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.