SOUTH ROBESON FARM

Operating

Solar power plant

Capacity
5 MW
Primary fuel
Solar
County
Robeson County
Operator
SOUTH ROBESON FARM LLC
Status
Operating
Commissioned
2012
EIA plant ID
58273
Coordinates
34.5611, -79.2797

See it on the map

SOUTH ROBESON FARM, a 5 MW Solar power plant in Robeson County, North Carolina. Operated by SOUTH ROBESON FARM LLC, commissioned 2012.

Weather peril exposure

SOUTH ROBESON FARM is a 5 MW solar power plant in Robeson County, NC, operated by SOUTH ROBESON FARM LLC, commissioned in 2012. Robeson County carries high modeled catastrophe exposure in the FEMA National Risk Index, scoring 3.5 of 5 at the 63rd national percentile. Hurricane is the leading peril, rated Relatively High by FEMA at the 91st percentile.

3.5 of 5Modeled catastrophe exposure
HighExposure band
HurricaneLeading peril
ConstrainedInsurability signal

Robeson County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
HurricaneRelatively High91st4.6 of 554%0.25
EarthquakeRelatively Moderate81st4.2 of 5<1%<0.01
Strong windVery High77th4.1 of 55%2.9
Ice stormRelatively High74th4.0 of 51%0.86
WildfireRelatively Low72nd3.9 of 51%<0.01
TornadoRelatively High55th3.2 of 55%0.54
LightningRelatively High53rd3.1 of 5<1%55.4
HailRelatively Moderate44th2.8 of 530%3.6
Heat waveRelatively Moderate38th2.5 of 5<1%7.7
Riverine floodingRelatively Moderate31st2.2 of 53%0.71
Winter weatherRelatively High25th2.0 of 5<1%2.6

Perils not assessed in Robeson County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 2.8 of 5, which sits in the 2% to 5% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 4.6 of 5, indicating a 5% to 10% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 2% to 5% of insured value. Wind deductible range: 5% to 10%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 5 MW solar array

At an assumed replacement value of $0.90 per watt, or $4.5M insured, the modeled expected annual loss for a fixed tilt ground mount array in Robeson County is $5,315 a year, $1,063 per MW, 0.12% of insured value.

Heat is modeled as a production risk rather than a property loss: 1.1% of annual yield in this county.

Insurability signal: Constrained. Named windstorm and severe wind at 4.6 of 5.

Model hail, wind and flood exposure for Robeson County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.