GLEASON GENERATING FACILITY

Operating

Natural Gas power plant

Capacity
568 MW
Primary fuel
Natural Gas
County
Weakley County
Operator
TENNESSEE VALLEY AUTHORITY
Status
Operating
Commissioned
2000
EIA plant ID
55251
Generators
3
Technology
Natural Gas Fired Combustion Turbine
Net generation (2024)
186 GWh
Capacity factor (2024, EIA nameplate)
3.7%
Data vintage
EIA-860 2024 final; EIA-923 2022-2024 final
Coordinates
36.2464, -88.6112

See it on the map

GLEASON GENERATING FACILITY, a 568 MW Natural Gas power plant in Weakley County, Tennessee. Operated by TENNESSEE VALLEY AUTHORITY, commissioned 2000.

How GLEASON GENERATING FACILITY compares

With 568 MW of capacity, GLEASON GENERATING FACILITY ranks 10th among the 53 operating power plants Bywatts maps in Tennessee and 2nd of the 5 operating Natural Gas plants in the state. It accounts for about 21% of Tennessee's operating Natural Gas capacity and 2.8% of all operating capacity in the state. Nationally it is the 285th-largest of the 1,185 operating Natural Gas plants in the database. Commissioned in 2000, it is newer than 77% of the 53 operating Tennessee plants with a recorded commissioning year. Its operator, TENNESSEE VALLEY AUTHORITY, runs 32 operating plants in Tennessee totaling 19,142 MW.

EIA-860 lists 3 generators at the site with 568 MW of nameplate capacity, all natural gas fired combustion turbine technology. Net generation was 186 GWh in 2024 (a 3.7% capacity factor).

Grid neighborhood

The nearest named substation is GLEASON, about 0.1 miles away; the closest transmission line found within 10 miles is a 500 kV line owned by TENNESSEE VALLEY AUTHORITY, under 0.1 miles away.

Computed by Bywatts from HIFLD power plant, substation and transmission line records and EIA-860/923 survey data; distances are straight-line. Sources and methodology

Weather peril exposure

GLEASON GENERATING FACILITY is a 568 MW natural gas power plant in Weakley County, TN, operated by TENNESSEE VALLEY AUTHORITY, commissioned in 2000. Weakley County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 2.2 of 5 at the 31st national percentile. Earthquake is the leading peril, rated Relatively Moderate by FEMA at the 98th percentile.

The Bywatts loss layer is calibrated to solar PV hardware, so it is not applied to a natural gas plant. The ratings below are the FEMA National Risk Index county hazard ratings for this location.

2.2 of 5Modeled catastrophe exposure
ModerateExposure band
EarthquakeLeading peril
Relatively LowFEMA county risk rating

Weakley County hazard ratings

PerilFEMA ratingNational percentilePeril scoreEvents per year
EarthquakeRelatively Moderate98th4.9 of 50.01
TornadoRelatively Moderate92nd4.7 of 50.48
Ice stormRelatively Moderate90th4.6 of 51.4
Winter weatherRelatively Moderate89th4.6 of 57.2
Strong windRelatively Moderate71st3.8 of 53.0
LightningRelatively High50th3.0 of 557.3
Heat waveRelatively Low50th3.0 of 512.2
HurricaneVery Low43rd2.7 of 50.03
HailVery Low24th2.0 of 52.8
WildfireVery Low20th1.8 of 5<0.01
Riverine floodingVery Low8th1.3 of 50.96

Perils not assessed in Weakley County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
Coastal floodingFEMA rating is "Not Applicable" for this county

Model hail, wind and flood exposure for Weakley County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level.