PANOCHE VALLEY SOLAR FARM

Operating

Solar power plant

Capacity
399 MW
Primary fuel
Solar
County
San Benito County
Operator
PANOCHE VALLEY SOLAR LLC
Status
Operating
Commissioned
2018
EIA plant ID
57340
Coordinates
36.7801, -120.7298

See it on the map

PANOCHE VALLEY SOLAR FARM, a 399 MW Solar power plant in San Benito County, California. Operated by PANOCHE VALLEY SOLAR LLC, commissioned 2018.

How PANOCHE VALLEY SOLAR FARM compares

With 399 MW of capacity, PANOCHE VALLEY SOLAR FARM ranks 39th among the 874 operating power plants Bywatts maps in California and 2nd of the 303 operating Solar plants in the state. It accounts for about 5.4% of California's operating Solar capacity and 0.6% of all operating capacity in the state. Nationally it is the 2nd-largest of the 639 operating Solar plants in the database. Commissioned in 2018, it is newer than 98% of the 859 operating California plants with a recorded commissioning year. It shares San Benito County with 2 other operating plants, ENERPARC CA1 LLC and HOLLISTER SOLAR LLC.

Grid neighborhood

The nearest named substation is SAN LUIS 5, under 0.1 miles away; the closest transmission line found within 10 miles is a 230 kV line owned by PACIFIC GAS & ELECTRIC COMPANY, about 1.3 miles away. Another 7 operating power plants totaling 775 MW sit within 25 miles; the largest is PANOCHE ENERGY CENTER (432 MW, Natural Gas).

Computed by Bywatts from HIFLD power plant, substation and transmission line records and EIA-860 retirement records; distances are straight-line. Sources and methodology

Weather peril exposure

PANOCHE VALLEY SOLAR FARM is a 399 MW solar power plant in San Benito County, CA, operated by PANOCHE VALLEY SOLAR LLC, commissioned in 2018. San Benito County carries moderate modeled catastrophe exposure in the FEMA National Risk Index, scoring 2.0 of 5 at the 24th national percentile. Earthquake is the leading peril, rated Relatively Moderate by FEMA at the 100th percentile.

2.0 of 5Modeled catastrophe exposure
ModerateExposure band
EarthquakeLeading peril
StandardInsurability signal

San Benito County hazard ratings

PerilFEMA ratingNational percentilePeril scoreShare of modeled lossEvents per year
EarthquakeRelatively Moderate100th5.0 of 537%0.19
WildfireRelatively Moderate98th4.9 of 545%<0.01
Riverine floodingRelatively Low81st4.2 of 515%0.29
Heat waveRelatively Low71st3.8 of 5<1%8.2
TornadoVery Low11th1.4 of 51%0.12
HailVery Low2nd1.1 of 51%0.10
Strong windVery Low2nd1.1 of 5<1%0.03
Winter weatherVery Low2nd1.1 of 5<1%1.5
LightningVery Low2nd1.1 of 5<1%3.2

Perils not assessed in San Benito County

These perils carry no usable National Risk Index figure for this county, so they are excluded from the scoring rather than scored zero. A zero would claim the peril was assessed and found benign.

PerilWhy it is not scored
HurricaneFEMA rating is "Not Applicable" for this county
Coastal floodingFEMA rating is "Not Applicable" for this county
Ice stormFEMA rating is "Not Applicable" for this county

Hail exposure and deductible structure

Hail scores 1.1 of 5, which sits in the 1% to 2% percentage deductible range carriers are quoting for that exposure. Named windstorm and severe convective wind score 1.4 of 5, indicating a 1% to 1% wind deductible. Ranges, not single figures. The final structure is set by the carrier.

Percentage hail deductible range: 1% to 2% of insured value. Wind deductible range: 1% to 1%. These are the structures commonly seen at this exposure, not an offer and not a rate.

Modeled annual loss for a 399 MW solar array

At an assumed replacement value of $0.90 per watt, or $359.1M insured, the modeled expected annual loss for a fixed tilt ground mount array in San Benito County is $140,180 a year, $351 per MW, 0.04% of insured value.

Heat is modeled as a production risk rather than a property loss: 2.1% of annual yield in this county.

Insurability signal: Standard. Wildfire carries 45% of modeled loss.

Model hail, wind and flood exposure for San Benito County in the weather risk calculator

Ratings are the FEMA National Risk Index county hazard ratings; the peril score is a Bywatts transform of the FEMA national percentile, and the modeled loss applies the Bywatts solar vulnerability layer. Full data sources and the solar vulnerability methodology are in the weather risk calculator.

Modeled estimate for screening and negotiation. Built from FEMA National Risk Index county hazard data and a solar vulnerability layer documented above. Not a quote, a binder, or actuarial advice, and not a substitute for a carrier's own model. Hazard data: FEMA National Risk Index December 2025, synced 2026-07-24. Resolution is county level, not site level. The solar vulnerability layer that turns FEMA building loss into modeled solar loss was derived by Bywatts and revised on physical reasoning. It has not been reviewed by a practising underwriter.